JentooBiology

AP® Biology · Unit 9

Investigation 6: Cellular Respiration and the Respirometer

A respirometer measures oxygen consumption during cellular respiration by tracking how far a water bead moves in a sealed tube, after potassium hydroxide removes the CO2 that would otherwise cancel out the pressure change.

Germinating peas respire: they take in O2 and release CO2 in roughly equal amounts. If both gases stayed in the tube, the total gas volume wouldn't change much, and the water bead in the pipette wouldn't move. Potassium hydroxide (KOH) solves this by absorbing the CO2 the peas release, converting it to a solid carbonate. That leaves only O2 being removed from the sealed air space, so total gas volume drops, pressure inside falls, and the water bead gets pulled toward the tube as outside air pressure pushes it in. The distance the bead travels, converted to volume, tells you how much O2 was consumed.

Every real respirometer needs a control tube built the same way but filled with dead or inert beads instead of living peas, plus KOH. This control accounts for changes in temperature, atmospheric pressure, or humidity during the experiment, any of which can shift gas volume and move the bead even with no respiration happening. You subtract the control's bead movement from the experimental tube's movement to isolate the volume change caused by respiration alone, not by the weather in the room.

This investigation sits alongside the course's other rate-based labs: you're again turning a physical measurement, bead displacement, into a rate, then asking what biological variable explains differences in that rate. Here the variable is metabolic state. A dormant seed's cells are in minimal-maintenance mode, so oxygen uptake is low and steady. A germinating seed switches on active growth, breaking down stored starches and lipids for energy, so its mitochondria run harder and oxygen consumption climbs sharply. Comparing germinating versus dormant peas, or peas at two temperatures, is the standard way this lab is extended.

Key terms

Respirometer
A sealed chamber that measures gas volume change caused by an organism's respiration.
Potassium hydroxide (KOH)
A chemical that absorbs CO2 from the air in the respirometer, leaving only O2 consumption to change the volume.
Control respirometer
An identical setup with dead or inert material used to measure volume changes from factors other than respiration.
Respiration rate
The volume of oxygen consumed per unit time, typically expressed in microliters per minute.
Germination
The early active growth stage of a seed, marked by sharply increased metabolic and respiratory activity.

Watch it explained

  1. How it worksHow does potassium hydroxide absorbing carbon dioxide make the volume change readable?
  2. How it worksWalk me through why the setup needs a control respirometer with dead beads in it.
  3. Worked exampleFind the respiration rate in microliters per minute from 0.4 mL consumed in 20 minutes.
  4. Going furtherWhy doesn't a dormant seed show the same oxygen uptake as a germinating one?

Check yourself

Your turn1 of 2
A respirometer shows 1.42 milliliters of oxygen consumed over 41 minutes. Find the respiration rate in microliters per minute (1 milliliter equals 1000 microliters).

End of topic.